99.99% uptime
Service availability target
Always-on protection
DDoS mitigation included
24/7 technical support
Available around the clock
UK infrastructure
Three active locations

Know where your service runs

Compare the connectivity, power, cooling and physical safeguards supporting each xHosts location. Service availability varies by product.

Diverse connectivity
Multiple fibre paths, carrier choice and resilient routing reduce dependence on a single route.
Operational resilience
UPS systems, standby generation and redundant cooling protect the hosting environment.
Layered protection
Controlled access, continuous monitoring and multi-stage fire detection secure the data halls.

Maidenhead

Our Maidenhead hosting location combines proximity to London with a large, resilient facility designed for demanding production infrastructure.

South East England
Facility standard
Tier 3
Technical floor area
2,800m²
Controlled temperature
22°C ±2°C
Fibre diversity
3 diverse routes

Network & speed

  • Three diverse fibre routes through multiple carriers
  • Cross-connects to several Tier 1 carriers
  • Direct peering interconnection to London LINX, Telehouse and Equinix facilities
  • Redundant core switching and routing architecture

Power

  • Two diverse 11kV, 8MVA utility feeds on separate physical routes
  • Six 600kVA and four 500kVA UPS units in an N+1 configuration
  • Six 1.5MVA backup generators in an N+1 configuration
  • Up to 36 hours initial generator operation at full occupancy

Cooling

  • N+1 redundant computer-room air conditioning
  • Redundant air-handling units for continuous fresh airflow
  • Controlled at 22°C ±2°C
  • Published cooling density of 75kW/m² and PUE of 1.6

Communications providers

  • BT
  • Level 3
  • Virgin Media
  • Zayo

Security

  • Manned and monitored 24/7/365
  • Three-metre secure perimeter fence and controlled pedestrian and vehicle access
  • Proximity-card or biometric access to data halls
  • Internal and external CCTV with 90-day recording

Fire & environment

  • Dual-zone detection with Fike gas suppression
  • VESDA early-warning smoke detection throughout
  • Double-knock activation protects against accidental discharge
  • Fluid detection integrated with air-conditioning units

Manchester

Our Manchester presence at Trafford Wharf provides well-connected northern infrastructure with resilient power, cooling and layered physical protection.

Trafford Wharf, North West England
Facility standard
Tier 2
Technical floor area
540m²
Controlled temperature
24°C ±2°C
Fibre diversity
2 diverse routes

Network & speed

  • Two diverse fibre routes through multiple carriers
  • Cross-connects to several Tier 1 carriers
  • Direct peering interconnection to London LINX, Telehouse and Equinix facilities
  • Multiple redundant core switches and routers

Power

  • 1MVA, 6.6kV utility supply
  • Four 200kVA UPS units with battery backup
  • Two 450kVA standby generators
  • Up to 24 hours initial generator operation at full occupancy

Cooling

  • N+1 redundant computer-room air conditioning
  • Published cooling density of 10kW/m²
  • Controlled at 24°C ±2°C
  • Published PUE of 1.5

Communications providers

  • BT
  • CenturyLink
  • Gamma
  • Hurricane Electric
  • SSE
  • The Loop
  • Vodafone
  • Zayo

Security

  • Manned and monitored 24/7/365
  • Proximity-card access to the data hall
  • Internal and external CCTV with 90-day recording
  • Security-breach alarms and discreet external design

Fire & environment

  • Dual-zone detection with gas fire suppression
  • VESDA early-warning smoke detection throughout
  • Double-knock activation protects against accidental discharge
  • Under-floor leak detection

Glasgow

Our Glasgow location supports Scottish and northern workloads from a purpose-built facility with diverse connectivity and round-the-clock on-site monitoring.

Scotland
Facility standard
Tier 2
Technical floor area
768m²
Controlled temperature
24°C ±2°C
Fibre diversity
2 diverse entries

Network & speed

  • Two diverse fibre entry points through multiple carriers
  • Cross-connects to several Tier 1 carriers
  • Direct peering interconnection to London LINX, Telehouse and Equinix facilities
  • Redundant core switching and routing architecture

Power

  • 1MVA, 11kV utility supply from a resilient ring main
  • Two 500kVA UPS systems
  • Standby generator provision
  • Up to 36 hours initial generator operation at full occupancy

Cooling

  • N+1 redundant computer-room air conditioning
  • Redundant air-handling units for continuous fresh airflow
  • Controlled at 24°C ±2°C
  • Published cooling density of 0.75kW/m² and PUE of 1.9

Communications providers

  • BT
  • CityFibre
  • Cogent
  • Level 3
  • Virgin Media
  • Zayo

Security

  • Manned and monitored 24/7/365
  • Three-metre secure perimeter fence and controlled access points
  • Proximity-card and PIN access to the data hall
  • Internal and external CCTV with 90-day recording

Fire & environment

  • Dual-zone detection with FM200 gas suppression
  • Double-knock activation protects against accidental discharge
  • Fire controls at access and egress points
  • Under-floor leak detection

Planning a deployment?

Our UK support team is available 24/7 to help you choose a location, port speed and transfer allowance.